004671271
ED2 125/3
Blokslēdzis
Switch disconnectors 125-1600A
Rated current:
125
No. Of poles:
3
Utilization category:
AC-23A, DC-22A
Standards:
IEC 60947-3
Rated impulse withstand voltage Uimp (kV):
8kV
Rated operational voltage (V AC):
690
Rated insulation voltage (V):
800V
Rated operational voltage (V DC):
250
Rated short-circuit making capacity Icm:
3,6
Rated short-time withstand current Icw at 0,3s:
2
004671272
ED2 160/3
Blokslēdzis
Switch disconnectors 125-1600A
Rated current:
160
No. Of poles:
3
Utilization category:
AC-23A, DC-22A
Standards:
IEC 60947-3
Rated impulse withstand voltage Uimp (kV):
8kV
Rated operational voltage (V AC):
690
Rated insulation voltage (V):
800V
Rated operational voltage (V DC):
250
Rated short-circuit making capacity Icm:
6
Rated short-time withstand current Icw at 0,3s:
3
004671273
ED2 250/3
Blokslēdzis
Switch disconnectors 125-1600A
Rated current:
250
No. Of poles:
3
Utilization category:
AC-23A, DC-22A
Standards:
IEC 60947-3
Rated impulse withstand voltage Uimp (kV):
8kV
Rated operational voltage (V AC):
690
Rated insulation voltage (V):
800V
Rated operational voltage (V DC):
250
Rated short-circuit making capacity Icm:
6
Rated short-time withstand current Icw at 0,3s:
3
004671274
ED2 400/3
Blokslēdzis
Switch disconnectors 125-1600A
Rated current:
400
No. Of poles:
3
Utilization category:
AC-23A, DC-22A
Standards:
IEC 60947-3
Rated impulse withstand voltage Uimp (kV):
8kV
Rated operational voltage (V AC):
690
Rated insulation voltage (V):
800V
Rated operational voltage (V DC):
250
Rated short-circuit making capacity Icm:
9
Rated short-time withstand current Icw at 0,3s:
5
004671275
ED2 630/3
Blokslēdzis
Switch disconnectors 125-1600A
Rated current:
630
No. Of poles:
3
Utilization category:
AC-23A, DC-22A
Standards:
IEC 60947-3
Rated impulse withstand voltage Uimp (kV):
8kV
Rated operational voltage (V AC):
690
Rated insulation voltage (V):
800V
Rated operational voltage (V DC):
250
Rated short-circuit making capacity Icm:
9
Rated short-time withstand current Icw at 0,3s:
5
004672370
ED2 800/3
Blokslēdzis
Switch disconnectors 125-1600A
Rated current:
800
No. Of poles:
3
Utilization category:
AC-23A, DC-22A
Standards:
IEC 60947-3
Rated impulse withstand voltage Uimp (kV):
8kV
Rated operational voltage (V AC):
690
Rated insulation voltage (V):
800V
Rated operational voltage (V DC):
250
Rated short-circuit making capacity Icm:
17
Rated short-time withstand current Icw at 0,3s:
10
004672371
ED2 1250/3
Blokslēdzis
Switch disconnectors 125-1600A
Rated current:
1250
No. Of poles:
3
Utilization category:
AC-23A, DC-22A
Standards:
IEC 60947-3
Rated impulse withstand voltage Uimp (kV):
8kV
Rated operational voltage (V AC):
690
Rated insulation voltage (V):
800V
Rated operational voltage (V DC):
250
Rated short-circuit making capacity Icm:
32
Rated short-time withstand current Icw at 0,3s:
15
004672372
ED2 1600/3 FC
Blokslēdzis
Switch disconnectors 125-1600A
Rated current:
1600
No. Of poles:
3
Utilization category:
AC-23A, DC-22A
Standards:
IEC 60947-3
Rated impulse withstand voltage Uimp (kV):
8kV
Rated operational voltage (V AC):
690
Rated insulation voltage (V):
800V
Rated operational voltage (V DC):
250
Rated short-circuit making capacity Icm:
45
Rated short-time withstand current Icw at 0,3s:
20
004671276
ED2 125/4
Blokslēdzis
Switch disconnectors 125-1600A
Rated current:
125
No. Of poles:
4
Utilization category:
AC-23A, DC-22A
Standards:
IEC 60947-3
Rated impulse withstand voltage Uimp (kV):
8kV
Rated operational voltage (V AC):
690
Rated insulation voltage (V):
800V
Rated operational voltage (V DC):
250
Rated short-circuit making capacity Icm:
3,6
Rated short-time withstand current Icw at 0,3s:
2
004671277
ED2 160/4
Blokslēdzis
Switch disconnectors 125-1600A
Rated current:
160
No. Of poles:
4
Utilization category:
AC-23A, DC-22A
Standards:
IEC 60947-3
Rated impulse withstand voltage Uimp (kV):
8kV
Rated operational voltage (V AC):
690
Rated insulation voltage (V):
800V
Rated operational voltage (V DC):
250
Rated short-circuit making capacity Icm:
6
Rated short-time withstand current Icw at 0,3s:
3
004671278
ED2 250/4
Blokslēdzis
Switch disconnectors 125-1600A
Rated current:
250
No. Of poles:
4
Utilization category:
AC-23A, DC-22A
Standards:
IEC 60947-3
Rated impulse withstand voltage Uimp (kV):
8kV
Rated operational voltage (V AC):
690
Rated insulation voltage (V):
800V
Rated operational voltage (V DC):
250
Rated short-circuit making capacity Icm:
6
Rated short-time withstand current Icw at 0,3s:
3
004671279
ED2 400/4
Blokslēdzis
Switch disconnectors 125-1600A
Rated current:
400
No. Of poles:
4
Utilization category:
AC-23A, DC-22A
Standards:
IEC 60947-3
Rated impulse withstand voltage Uimp (kV):
8kV
Rated operational voltage (V AC):
690
Rated insulation voltage (V):
800V
Rated operational voltage (V DC):
250
Rated short-circuit making capacity Icm:
9
Rated short-time withstand current Icw at 0,3s:
5
004671280
ED2 630/4
Blokslēdzis
Switch disconnectors 125-1600A
Rated current:
630
No. Of poles:
4
Utilization category:
AC-23A, DC-22A
Standards:
IEC 60947-3
Rated impulse withstand voltage Uimp (kV):
8kV
Rated operational voltage (V AC):
690
Rated insulation voltage (V):
800V
Rated operational voltage (V DC):
250
Rated short-circuit making capacity Icm:
9
Rated short-time withstand current Icw at 0,3s:
5
004672380
ED2 800/4
Blokslēdzis
Switch disconnectors 125-1600A
Rated current:
800
No. Of poles:
4
Utilization category:
AC-23A, DC-22A
Standards:
IEC 60947-3
Rated impulse withstand voltage Uimp (kV):
8kV
Rated operational voltage (V AC):
690
Rated insulation voltage (V):
800V
Rated operational voltage (V DC):
250
Rated short-circuit making capacity Icm:
17
Rated short-time withstand current Icw at 0,3s:
10
004672381
ED2 1250/4
Blokslēdzis
Switch disconnectors 125-1600A
Rated current:
1250
No. Of poles:
4
Utilization category:
AC-23A, DC-22A
Standards:
IEC 60947-3
Rated impulse withstand voltage Uimp (kV):
8kV
Rated operational voltage (V AC):
690
Rated insulation voltage (V):
800V
Rated operational voltage (V DC):
250
Rated short-circuit making capacity Icm:
32
Rated short-time withstand current Icw at 0,3s:
15
004672382
ED2 1600/4 FC
Blokslēdzis
Switch disconnectors 125-1600A
Rated current:
1600
No. Of poles:
4
Utilization category:
AC-23A, DC-22A
Standards:
IEC 60947-3
Rated impulse withstand voltage Uimp (kV):
8kV
Rated operational voltage (V AC):
690
Rated insulation voltage (V):
800V
Rated operational voltage (V DC):
250
Rated short-circuit making capacity Icm:
45
Rated short-time withstand current Icw at 0,3s:
20
004672374
ED2 1250/3 PI 3C
Blokslēdzis
Switch disconnectors 125-1600A
Rated current:
1250
No. Of poles:
3
Utilization category:
AC-23A, DC-22A
Standards:
IEC 60947-3
Rated impulse withstand voltage Uimp (kV):
8kV
Rated operational voltage (V AC):
690
Rated insulation voltage (V):
800V
Rated operational voltage (V DC):
250
Rated short-circuit making capacity Icm:
32
Rated short-time withstand current Icw at 0,3s:
15
004672383
ED2 1000/4
Blokslēdzis
Switch disconnectors 125-1600A
Rated current:
1000
No. Of poles:
4
Utilization category:
AC-23A, DC-22A
Standards:
IEC 60947-3
Rated impulse withstand voltage Uimp (kV):
8kV
Rated operational voltage (V AC):
690
Rated insulation voltage (V):
800V
Rated operational voltage (V DC):
250
Rated short-circuit making capacity Icm:
17
Rated short-time withstand current Icw at 0,3s:
10
004672373
ED2 1000/3
Blokslēdzis
Switch disconnectors 125-1600A
Rated current:
1000
No. Of poles:
3
Utilization category:
AC-23A, DC-22A
Standards:
IEC 60947-3
Rated impulse withstand voltage Uimp (kV):
8kV
Rated operational voltage (V AC):
690
Rated insulation voltage (V):
800V
Rated operational voltage (V DC):
250
Rated short-circuit making capacity Icm:
17
Rated short-time withstand current Icw at 0,3s:
10