002625400
CH10x38 MM 2A/1000V AC/DC
Drošinātājs
Multimeter and metering fuses
pim_status:
Rated current:
2
Type:
CH
Size:
CH10
Characteristics:
gR
Rated DC voltage:
1000
Dimensions:
10x38
Indicator:
Breaking capacity DC:
30
Pd (W):
0,9
Standards:
IEC 60269-4
Power dissipation (0,7xIn) (W):
Operating joule integral (A2s):
L/R (ms):
Prearcing joule integral (A2s):
Application:
Multimeter fused
UL certificate:
002625401
CH10x38 MM 4A/1000V AC/DC
Drošinātājs
Multimeter and metering fuses
pim_status:
Rated current:
4
Type:
CH
Size:
CH10
Characteristics:
gR
Rated DC voltage:
1000
Dimensions:
10x38
Indicator:
Breaking capacity DC:
30
Pd (W):
1,2
Standards:
IEC 60269-4
Power dissipation (0,7xIn) (W):
Operating joule integral (A2s):
L/R (ms):
Prearcing joule integral (A2s):
Application:
Multimeter fused
UL certificate:
002625402
CH10x38 MM 6A/1000V AC/DC
Drošinātājs
Multimeter and metering fuses
pim_status:
Rated current:
6
Type:
CH
Size:
CH10
Characteristics:
gR
Rated DC voltage:
1000
Dimensions:
10x38
Indicator:
Breaking capacity DC:
30
Pd (W):
1,6
Standards:
IEC 60269-4
Power dissipation (0,7xIn) (W):
Operating joule integral (A2s):
L/R (ms):
Prearcing joule integral (A2s):
Application:
Multimeter fused
UL certificate:
002625403
CH10x38 MM 8A/1000V AC/DC
Drošinātājs
Multimeter and metering fuses
pim_status:
Rated current:
8
Type:
CH
Size:
CH10
Characteristics:
gR
Rated DC voltage:
1000
Dimensions:
10x38
Indicator:
Breaking capacity DC:
30
Pd (W):
1,8
Standards:
IEC 60269-4
Power dissipation (0,7xIn) (W):
Operating joule integral (A2s):
L/R (ms):
Prearcing joule integral (A2s):
Application:
Multimeter fused
UL certificate:
002625404
CH10x38 MM 10A/1000V AC/DC
Drošinātājs
Multimeter and metering fuses
pim_status:
Rated current:
10
Type:
CH
Size:
CH10
Characteristics:
gR
Rated DC voltage:
1000
Dimensions:
10x38
Indicator:
Breaking capacity DC:
30
Pd (W):
2,1
Standards:
IEC 60269-4
Power dissipation (0,7xIn) (W):
Operating joule integral (A2s):
L/R (ms):
Prearcing joule integral (A2s):
Application:
Multimeter fused
UL certificate:
002625405
CH10x38 MM 12A/1000V AC/DC
Drošinātājs
Multimeter and metering fuses
pim_status:
Rated current:
12
Type:
CH
Size:
CH10
Characteristics:
gR
Rated DC voltage:
1000
Dimensions:
10x38
Indicator:
Breaking capacity DC:
30
Pd (W):
1,7
Standards:
IEC 60269-4
Power dissipation (0,7xIn) (W):
Operating joule integral (A2s):
L/R (ms):
Prearcing joule integral (A2s):
Application:
Multimeter fused
UL certificate:
002625406
CH10x38 MM 16A/1000V AC/DC
Drošinātājs
Multimeter and metering fuses
pim_status:
Rated current:
16
Type:
CH
Size:
CH10
Characteristics:
gR
Rated DC voltage:
1000
Dimensions:
10x38
Indicator:
Breaking capacity DC:
30
Pd (W):
2,3
Standards:
IEC 60269-4
Power dissipation (0,7xIn) (W):
Operating joule integral (A2s):
L/R (ms):
Prearcing joule integral (A2s):
Application:
Multimeter fused
UL certificate:
002625407
CH10x38 MM 20A/1000V AC/DC
Drošinātājs
Multimeter and metering fuses
pim_status:
Rated current:
20
Type:
CH
Size:
CH10
Characteristics:
gR
Rated DC voltage:
1000
Dimensions:
10x38
Indicator:
Breaking capacity DC:
30
Pd (W):
3,15
Standards:
IEC 60269-4
Power dissipation (0,7xIn) (W):
Operating joule integral (A2s):
L/R (ms):
Prearcing joule integral (A2s):
Application:
Multimeter fused
UL certificate:
004113835
NH1 gG 80A/400V MET
Drošinātājs
Multimeter and metering fuses
pim_status:
Rated current:
80
Type:
NH
Size:
NH1
Characteristics:
gG
Rated DC voltage:
Dimensions:
Indicator:
Top fuse status indicator
Breaking capacity DC:
Pd (W):
5,2
Standards:
IEC EN 60269-1
Power dissipation (0,7xIn) (W):
Operating joule integral (A2s):
L/R (ms):
Prearcing joule integral (A2s):
Application:
As metering fuse with strip fuse switch disconnector and fuse switch disconnector
UL certificate:
004113836
NH1 gG 100A/400V MET
Drošinātājs
Multimeter and metering fuses
pim_status:
Rated current:
100
Type:
NH
Size:
NH1
Characteristics:
gG
Rated DC voltage:
Dimensions:
Indicator:
Top fuse status indicator
Breaking capacity DC:
Pd (W):
6,2
Standards:
IEC EN 60269-1
Power dissipation (0,7xIn) (W):
Operating joule integral (A2s):
L/R (ms):
Prearcing joule integral (A2s):
Application:
As metering fuse with strip fuse switch disconnector and fuse switch disconnector
UL certificate:
004113837
NH1 gG 125A/400V MET
Drošinātājs
Multimeter and metering fuses
pim_status:
Rated current:
125
Type:
NH
Size:
NH1
Characteristics:
gG
Rated DC voltage:
Dimensions:
Indicator:
Top fuse status indicator
Breaking capacity DC:
Pd (W):
7,9
Standards:
IEC EN 60269-1
Power dissipation (0,7xIn) (W):
Operating joule integral (A2s):
L/R (ms):
Prearcing joule integral (A2s):
Application:
As metering fuse with strip fuse switch disconnector and fuse switch disconnector
UL certificate:
004113838
NH1 gG 160A/400V MET
Drošinātājs
Multimeter and metering fuses
pim_status:
Rated current:
160
Type:
NH
Size:
NH1
Characteristics:
gG
Rated DC voltage:
Dimensions:
Indicator:
Top fuse status indicator
Breaking capacity DC:
Pd (W):
9
Standards:
IEC EN 60269-1
Power dissipation (0,7xIn) (W):
Operating joule integral (A2s):
L/R (ms):
Prearcing joule integral (A2s):
Application:
As metering fuse with strip fuse switch disconnector and fuse switch disconnector
UL certificate:
004113839
NH1 gG 200A/400V MET
Drošinātājs
Multimeter and metering fuses
pim_status:
Rated current:
200
Type:
NH
Size:
NH1
Characteristics:
gG
Rated DC voltage:
Dimensions:
Indicator:
Top fuse status indicator
Breaking capacity DC:
Pd (W):
12
Standards:
IEC EN 60269-1
Power dissipation (0,7xIn) (W):
Operating joule integral (A2s):
L/R (ms):
Prearcing joule integral (A2s):
Application:
As metering fuse with strip fuse switch disconnector and fuse switch disconnector
UL certificate:
004113840
NH1 gG 250A/400V MET
Drošinātājs
Multimeter and metering fuses
pim_status:
Rated current:
250
Type:
NH
Size:
NH1
Characteristics:
gG
Rated DC voltage:
Dimensions:
Indicator:
Top fuse status indicator
Breaking capacity DC:
Pd (W):
17
Standards:
IEC EN 60269-1
Power dissipation (0,7xIn) (W):
Operating joule integral (A2s):
L/R (ms):
Prearcing joule integral (A2s):
Application:
As metering fuse with strip fuse switch disconnector and fuse switch disconnector
UL certificate:
004113842
NH2 gG 80A/400V MET
Drošinātājs
Multimeter and metering fuses
pim_status:
Rated current:
80
Type:
NH
Size:
NH2
Characteristics:
gG
Rated DC voltage:
Dimensions:
Indicator:
Top fuse status indicator
Breaking capacity DC:
Pd (W):
5,2
Standards:
IEC EN 60269-1
Power dissipation (0,7xIn) (W):
Operating joule integral (A2s):
L/R (ms):
Prearcing joule integral (A2s):
Application:
As metering fuse with strip fuse switch disconnector and fuse switch disconnector
UL certificate:
004113843
NH2 gG 100A/400V MET
Drošinātājs
Multimeter and metering fuses
pim_status:
Rated current:
100
Type:
NH
Size:
NH2
Characteristics:
gG
Rated DC voltage:
Dimensions:
Indicator:
Top fuse status indicator
Breaking capacity DC:
Pd (W):
6,2
Standards:
IEC EN 60269-1
Power dissipation (0,7xIn) (W):
Operating joule integral (A2s):
L/R (ms):
Prearcing joule integral (A2s):
Application:
As metering fuse with strip fuse switch disconnector and fuse switch disconnector
UL certificate:
004113844
NH2 gG 125A/400V MET
Drošinātājs
Multimeter and metering fuses
pim_status:
Rated current:
125
Type:
NH
Size:
NH2
Characteristics:
gG
Rated DC voltage:
Dimensions:
Indicator:
Top fuse status indicator
Breaking capacity DC:
Pd (W):
7,9
Standards:
IEC EN 60269-1
Power dissipation (0,7xIn) (W):
Operating joule integral (A2s):
L/R (ms):
Prearcing joule integral (A2s):
Application:
As metering fuse with strip fuse switch disconnector and fuse switch disconnector
UL certificate:
004113845
NH2 gG 160A/400V MET
Drošinātājs
Multimeter and metering fuses
pim_status:
Rated current:
160
Type:
NH
Size:
NH2
Characteristics:
gG
Rated DC voltage:
Dimensions:
Indicator:
Top fuse status indicator
Breaking capacity DC:
Pd (W):
9
Standards:
IEC EN 60269-1
Power dissipation (0,7xIn) (W):
Operating joule integral (A2s):
L/R (ms):
Prearcing joule integral (A2s):
Application:
As metering fuse with strip fuse switch disconnector and fuse switch disconnector
UL certificate:
004113846
NH2 gG 200A/400V MET
Drošinātājs
Multimeter and metering fuses
pim_status:
Rated current:
200
Type:
NH
Size:
NH2
Characteristics:
gG
Rated DC voltage:
Dimensions:
Indicator:
Top fuse status indicator
Breaking capacity DC:
Pd (W):
12
Standards:
IEC EN 60269-1
Power dissipation (0,7xIn) (W):
Operating joule integral (A2s):
L/R (ms):
Prearcing joule integral (A2s):
Application:
As metering fuse with strip fuse switch disconnector and fuse switch disconnector
UL certificate:
004113847
NH2 gG 250A/400V MET
Drošinātājs
Multimeter and metering fuses
pim_status:
Rated current:
250
Type:
NH
Size:
NH2
Characteristics:
gG
Rated DC voltage:
Dimensions:
Indicator:
Top fuse status indicator
Breaking capacity DC:
Pd (W):
17
Standards:
IEC EN 60269-1
Power dissipation (0,7xIn) (W):
Operating joule integral (A2s):
L/R (ms):
Prearcing joule integral (A2s):
Application:
As metering fuse with strip fuse switch disconnector and fuse switch disconnector
UL certificate:
004113848
NH2 gG 315A/400V MET
Drošinātājs
Multimeter and metering fuses
pim_status:
Rated current:
315
Type:
NH
Size:
NH2
Characteristics:
gG
Rated DC voltage:
Dimensions:
Indicator:
Top fuse status indicator
Breaking capacity DC:
Pd (W):
20
Standards:
IEC EN 60269-1
Power dissipation (0,7xIn) (W):
Operating joule integral (A2s):
L/R (ms):
Prearcing joule integral (A2s):
Application:
As metering fuse with strip fuse switch disconnector and fuse switch disconnector
UL certificate:
004113849
NH2 gG 400A/400V MET
Drošinātājs
Multimeter and metering fuses
pim_status:
Rated current:
400
Type:
NH
Size:
NH2
Characteristics:
gG
Rated DC voltage:
Dimensions:
Indicator:
Top fuse status indicator
Breaking capacity DC:
Pd (W):
24
Standards:
IEC EN 60269-1
Power dissipation (0,7xIn) (W):
Operating joule integral (A2s):
L/R (ms):
Prearcing joule integral (A2s):
Application:
As metering fuse with strip fuse switch disconnector and fuse switch disconnector
UL certificate:
004113851
NH3 gG 200A/400V MET
Drošinātājs
Multimeter and metering fuses
pim_status:
Rated current:
200
Type:
NH
Size:
NH3
Characteristics:
gG
Rated DC voltage:
Dimensions:
Indicator:
Top fuse status indicator
Breaking capacity DC:
Pd (W):
12
Standards:
IEC EN 60269-1
Power dissipation (0,7xIn) (W):
Operating joule integral (A2s):
L/R (ms):
Prearcing joule integral (A2s):
Application:
As metering fuse with strip fuse switch disconnector and fuse switch disconnector
UL certificate:
004113852
NH3 gG 250A/400V MET
Drošinātājs
Multimeter and metering fuses
pim_status:
Rated current:
250
Type:
NH
Size:
NH3
Characteristics:
gG
Rated DC voltage:
Dimensions:
Indicator:
Top fuse status indicator
Breaking capacity DC:
Pd (W):
17
Standards:
IEC EN 60269-1
Power dissipation (0,7xIn) (W):
Operating joule integral (A2s):
L/R (ms):
Prearcing joule integral (A2s):
Application:
As metering fuse with strip fuse switch disconnector and fuse switch disconnector
UL certificate:
004113853
NH3 gG 315A/400V MET
Drošinātājs
Multimeter and metering fuses
pim_status:
Rated current:
315
Type:
NH
Size:
NH3
Characteristics:
gG
Rated DC voltage:
Dimensions:
Indicator:
Top fuse status indicator
Breaking capacity DC:
Pd (W):
20
Standards:
IEC EN 60269-1
Power dissipation (0,7xIn) (W):
Operating joule integral (A2s):
L/R (ms):
Prearcing joule integral (A2s):
Application:
As metering fuse with strip fuse switch disconnector and fuse switch disconnector
UL certificate:
004113854
NH3 gG 400A/400V MET
Drošinātājs
Multimeter and metering fuses
pim_status:
Rated current:
400
Type:
NH
Size:
NH3
Characteristics:
gG
Rated DC voltage:
Dimensions:
Indicator:
Top fuse status indicator
Breaking capacity DC:
Pd (W):
24
Standards:
IEC EN 60269-1
Power dissipation (0,7xIn) (W):
Operating joule integral (A2s):
L/R (ms):
Prearcing joule integral (A2s):
Application:
As metering fuse with strip fuse switch disconnector and fuse switch disconnector
UL certificate:
004113855
NH3 gG 500A/400V MET
Drošinātājs
Multimeter and metering fuses
pim_status:
Rated current:
500
Type:
NH
Size:
NH3
Characteristics:
gG
Rated DC voltage:
Dimensions:
Indicator:
Top fuse status indicator
Breaking capacity DC:
Pd (W):
27
Standards:
IEC EN 60269-1
Power dissipation (0,7xIn) (W):
Operating joule integral (A2s):
L/R (ms):
Prearcing joule integral (A2s):
Application:
As metering fuse with strip fuse switch disconnector and fuse switch disconnector
UL certificate:
004113856
NH3 gG 630A/400V MET
Drošinātājs
Multimeter and metering fuses
pim_status:
Rated current:
630
Type:
NH
Size:
NH3
Characteristics:
gG
Rated DC voltage:
Dimensions:
Indicator:
Top fuse status indicator
Breaking capacity DC:
Pd (W):
32
Standards:
IEC EN 60269-1
Power dissipation (0,7xIn) (W):
Operating joule integral (A2s):
L/R (ms):
Prearcing joule integral (A2s):
Application:
As metering fuse with strip fuse switch disconnector and fuse switch disconnector
UL certificate:
004113858
NH4a gG 630A/400V MET
Drošinātājs
Multimeter and metering fuses
pim_status:
Rated current:
630
Type:
NH
Size:
NH4a
Characteristics:
gG
Rated DC voltage:
Dimensions:
Indicator:
Top fuse status indicator
Breaking capacity DC:
Pd (W):
51
Standards:
IEC EN 60269-1
Power dissipation (0,7xIn) (W):
Operating joule integral (A2s):
L/R (ms):
Prearcing joule integral (A2s):
Application:
As metering fuse with strip fuse switch disconnector and fuse switch disconnector
UL certificate:
004113859
NH4a gG 800A/400V MET
Drošinātājs
Multimeter and metering fuses
pim_status:
Rated current:
800
Type:
NH
Size:
NH4a
Characteristics:
gG
Rated DC voltage:
Dimensions:
Indicator:
Top fuse status indicator
Breaking capacity DC:
Pd (W):
61
Standards:
IEC EN 60269-1
Power dissipation (0,7xIn) (W):
Operating joule integral (A2s):
L/R (ms):
Prearcing joule integral (A2s):
Application:
As metering fuse with strip fuse switch disconnector and fuse switch disconnector
UL certificate:
004113860
NH4a gG 1000A/400V MET
Drošinātājs
Multimeter and metering fuses
pim_status:
Rated current:
1000
Type:
NH
Size:
NH4a
Characteristics:
gG
Rated DC voltage:
Dimensions:
Indicator:
Top fuse status indicator
Breaking capacity DC:
Pd (W):
72
Standards:
IEC EN 60269-1
Power dissipation (0,7xIn) (W):
Operating joule integral (A2s):
L/R (ms):
Prearcing joule integral (A2s):
Application:
As metering fuse with strip fuse switch disconnector and fuse switch disconnector
UL certificate:
004113861
NH4a gG 1250A/400V MET
Drošinātājs
Multimeter and metering fuses
pim_status:
Rated current:
1250
Type:
NH
Size:
NH4a
Characteristics:
gG
Rated DC voltage:
Dimensions:
Indicator:
Top fuse status indicator
Breaking capacity DC:
Pd (W):
90
Standards:
IEC EN 60269-1
Power dissipation (0,7xIn) (W):
Operating joule integral (A2s):
L/R (ms):
Prearcing joule integral (A2s):
Application:
As metering fuse with strip fuse switch disconnector and fuse switch disconnector
UL certificate:
004113865
NH1 gTr 144A/400V 100kVA MET
Drošinātājs
Multimeter and metering fuses
pim_status:
Rated current:
100
Type:
NH
Size:
NH1
Characteristics:
gTr
Rated DC voltage:
Dimensions:
Indicator:
Top fuse status indicator
Breaking capacity DC:
Pd (W):
11
Standards:
IEC EN 60269-1
Power dissipation (0,7xIn) (W):
Operating joule integral (A2s):
L/R (ms):
Prearcing joule integral (A2s):
Application:
As metering fuse with strip fuse switch disconnector and fuse switch disconnector
UL certificate:
004113866
NH1 gTr 180A/400V 125kVA MET
Drošinātājs
Multimeter and metering fuses
pim_status:
Rated current:
125
Type:
NH
Size:
NH1
Characteristics:
gTr
Rated DC voltage:
Dimensions:
Indicator:
Top fuse status indicator
Breaking capacity DC:
Pd (W):
13
Standards:
IEC EN 60269-1
Power dissipation (0,7xIn) (W):
Operating joule integral (A2s):
L/R (ms):
Prearcing joule integral (A2s):
Application:
As metering fuse with strip fuse switch disconnector and fuse switch disconnector
UL certificate:
004113867
NH1 gTr 231A/400V 160kVA MET
Drošinātājs
Multimeter and metering fuses
pim_status:
Rated current:
160
Type:
NH
Size:
NH1
Characteristics:
gTr
Rated DC voltage:
Dimensions:
Indicator:
Top fuse status indicator
Breaking capacity DC:
Pd (W):
17
Standards:
IEC EN 60269-1
Power dissipation (0,7xIn) (W):
Operating joule integral (A2s):
L/R (ms):
Prearcing joule integral (A2s):
Application:
As metering fuse with strip fuse switch disconnector and fuse switch disconnector
UL certificate:
004113872
NH2 gTr 144A/400V 100kVA MET
Drošinātājs
Multimeter and metering fuses
pim_status:
Rated current:
100
Type:
NH
Size:
NH2
Characteristics:
gTr
Rated DC voltage:
Dimensions:
Indicator:
Top fuse status indicator
Breaking capacity DC:
Pd (W):
11
Standards:
IEC EN 60269-1
Power dissipation (0,7xIn) (W):
Operating joule integral (A2s):
L/R (ms):
Prearcing joule integral (A2s):
Application:
As metering fuse with strip fuse switch disconnector and fuse switch disconnector
UL certificate:
004113873
NH2 gTr 188A/400V 125kVA MET
Drošinātājs
Multimeter and metering fuses
pim_status:
Rated current:
125
Type:
NH
Size:
NH2
Characteristics:
gTr
Rated DC voltage:
Dimensions:
Indicator:
Top fuse status indicator
Breaking capacity DC:
Pd (W):
13
Standards:
IEC EN 60269-1
Power dissipation (0,7xIn) (W):
Operating joule integral (A2s):
L/R (ms):
Prearcing joule integral (A2s):
Application:
As metering fuse with strip fuse switch disconnector and fuse switch disconnector
UL certificate:
004113874
NH2 gTr 231A/400V 160kVA MET
Drošinātājs
Multimeter and metering fuses
pim_status:
Rated current:
160
Type:
NH
Size:
NH2
Characteristics:
gTr
Rated DC voltage:
Dimensions:
Indicator:
Top fuse status indicator
Breaking capacity DC:
Pd (W):
17
Standards:
IEC EN 60269-1
Power dissipation (0,7xIn) (W):
Operating joule integral (A2s):
L/R (ms):
Prearcing joule integral (A2s):
Application:
As metering fuse with strip fuse switch disconnector and fuse switch disconnector
UL certificate:
004113875
NH2 gTr 289A/400V 200kVA MET
Drošinātājs
Multimeter and metering fuses
pim_status:
Rated current:
200
Type:
NH
Size:
NH2
Characteristics:
gTr
Rated DC voltage:
Dimensions:
Indicator:
Top fuse status indicator
Breaking capacity DC:
Pd (W):
20
Standards:
IEC EN 60269-1
Power dissipation (0,7xIn) (W):
Operating joule integral (A2s):
L/R (ms):
Prearcing joule integral (A2s):
Application:
As metering fuse with strip fuse switch disconnector and fuse switch disconnector
UL certificate:
004113876
NH2 gTr 361A/400V 250kVA MET
Drošinātājs
Multimeter and metering fuses
pim_status:
Rated current:
250
Type:
NH
Size:
NH2
Characteristics:
gTr
Rated DC voltage:
Dimensions:
Indicator:
Top fuse status indicator
Breaking capacity DC:
Pd (W):
25
Standards:
IEC EN 60269-1
Power dissipation (0,7xIn) (W):
Operating joule integral (A2s):
L/R (ms):
Prearcing joule integral (A2s):
Application:
As metering fuse with strip fuse switch disconnector and fuse switch disconnector
UL certificate: